  1. TECHNICAL BULLETIN
  2. 09.27.91 AUTOCAD386 MWF (update 08.24.92)
  3. CAD SOFTWARE: AutoCAD 386 (Release 10C10 & Release 11), Autodesk,
  4. Inc.
  5.  
  6.  
  7. Comment:
  8. AutoCAD 386 (Release 10 C10 and Release 11) is listed as
  9. compatible with LANtastic NOS 3.0X and 4.X. The following
  10. information has been compiled from in-house testing and other
  11. resources on using AutoCAD 386 with LANtastic.
  12.  
  13. Guidelines for using AutoCAD 386 with LANtastic:
  14. 1. AutoCAD 11 is a very processor-time intensive application that
  15. runs in protected mode on an 386 or 486 computer. It can access
  16. up to 4 Gigabytes of memory (either in RAM or virtual disk
  17. space), however the program uses less than 250K of conventional
  18. RAM when loaded. If the workstation is only used for AutoCAD 386,
  19. there is no benefit to loading TSR's into high memory because the
  20. conventional memory requirements are very small.
  21.  
  22. 2. Using an AutoCAD workstation as a server for sharing a plotter
  23. or printer-plotter is not recommended since AutoCAD is a very
  24. processor-time intensive application. Performance of AutoCAD
  25. and/or the network can be severely reduced by background plotter
  26. or printer-plotter despooling (generally seen as slow or jerky
  27. crosshair movement). The ideal AutoCAD network configuration
  28. would include a dedicated server with harddrive and ports to
  29. control the plotter(s) and printer-plotter(s), thus allowing the
  30. AutoCAD workstations to have 100% of their own processor time
  31. available for AutoCAD functions.
  32.  
  33. 3. Set FCBS=16,8 and FILES=40 in CONFIG.SYS on workstations
  34. running AutoCAD 386. NOTE: If AutoCAD 10 (DOS) and AutoCAD 386
  35. will both be used on the same workstation running under DOS 4.01,
  36. set FCBS=48,8 in CONFIG.SYS.
  37.  
  38. 4. Protected-mode video Display List Drivers are available in ADI
  39. format to use with AutoCAD 386 and work very well. Some real-mode
  40. DLD's are also available and no compatibility problems have been
  41. reported with LANtastic. Switching between real and
  42. protected-mode can degrade performance, so using a protected-mode
  43. video driver is recommended for maximum performance.
  44.  
  45. 5. AutoCAD 386 loads entirely into RAM so there is no benefit to
  46. using a ramdisk [as far as AutoCAD 386 is concerned]. There are
  47. no overlay files, and if the workstation has enough RAM
  48. available, there will be only minimal disk access when editing a
  49. drawing. Whatever memory would be given to a ramdisk, would be
  50. taken away from AutoCAD 386. A small disk cache (256K) will
  51. improve performance when AutoCAD 386 is paging to disk. Don't
  52. give too much memory to caching as it will take memory away from
  53. AutoCAD and performance can suffer.
  54.  
  55. 6. AutoCAD 386 Rel. 11 has a file-locking feature that is
  56. software selectable and will prevent multiple access to a drawing
  57. file. This can be enabled from the AutoCAD main menu by selecting
  58. "5. Configure AutoCAD", "8. Configure operating parameters", "11.
  59. Server authorization and file locking". File locking in AutoCAD
  60. 386 does not require SHARE.EXE to be loaded to function.
  61.  
  62. 7. If using a common drawing fileserver, configure each AutoCAD
  63. workstation to have a unique network node name. From the AutoCAD
  64. main menu, select "5. Configure AutoCAD", "8. Configure operating
  65. parameters", "6. Network node name" and enter a three character
  66. name unique to each workstation.
  67.  
  68. 8. If plotter performance is slow, or pauses intermittently, on
  69. an AutoCAD 386 workstation/server that is sharing a plotter,
  70. increase the CPS to the plotter (using the max of 32767 is OK,
  71. but the tradeoff is poor AutoCAD 386 performance). NOTE: The only
  72. way to eliminate the performance degradation of an AutoCAD
  73. workstation during plotting or printer-plotting is to have the
  74. server not running AutoCAD during the despooling function. See
  75. note 2 on using a dedicated print server.
  76.  
  77. 9. To share a plotter or printer-plotter, AutoCAD must output to
  78. file. The important item to keep in mind is that AutoCAD 386
  79. never communicates with the plotter (or printer-plotter),
  80. instead, it outputs to a file on disk. All communication with the
  81. plotter or printer-plotter device(s) is handled by the network.
  82. Configure AutoCAD 386 to plot to a file, set the filename to the
  83. name of the port that is redirected to @PLOTTER. Set the LPT
  84. TIMEOUT to 0 (zero).
  85.  
  86. The recommended serial communication protocol for the network to
  87. the plotter is 9600, 8, 1, N, using XON/XOFF flow control. Some
  88. plotters that will only accept HARDWARE flow control require a
  89. HARDWARE cable - a straight-thru serial cable will not allow
  90. HARDWARE flow control communications. The next best protocol is
  91. 9600, 7, 1, E, XON/XOFF. If the plotter and @PLOTTER shared
  92. resource are not configured exactly the same, plotting will not
  93. be successful.
  94.  
  95. NOTE: If the plotter does not automatically go OFF-LINE at the
  96. completion of a plot, it is recommended to edit the SETUP STRING
  97. for @PLOTTER (located in NET_MGR, Shared Resources Management) to
  98. include the ASCII or <ESC> codes needed to take the plotter
  99. off-line at the start of a plot to allow for paper changes. If
  100. this is not done, it will be possible for multiple plot jobs in
  101. the spooler to be plotted over the same sheet of paper. If the
  102. plotter has an automatic paper feeder/cutter, this may not be
  103. necessary.
  104.  
  105. 10. AutoCAD 386 Release 11 has an environment variable that can
  106. be used to create and send spool files to a redirected plotter or
  107. printer-plotter automatically. The recommended configuration is
  108. as follows:
  109.  
  110.   1)   Create a directory under the ACAD directory called TEMP
  111.        (C:\ACAD\TEMP). Add that directory to the DOS environment
  112.        path (see "SAMPLE BATCH FILES:" at end of this document).
  113.   2)   Configure AutoCAD to put temporary files and the SPOOLED
  114.        print/plot files there as follows:
  115.      1)   From the AutoCAD main menu, select "5. Configure
  116.           AutoCAD". 
  117.      2)   Select "5. Configure plotter" and "6. Configure printer
  118.           plotter". Keep the same plotter and printer,
  119.      3)   Select "YES" when asked to output to a file.
  120.      4)   Select "8. Configure operating parameters."
  121.        A) Select "3. Default plot file name", enter "AUTOSPOOL".
  122.        NOTE: "AUTOSPOOL" must be in all capital letters.
  123.        B) Select "4. Plot spooler directory", enter
  124.        "C:\ACAD\TEMP\".
  125.      5)   Save the changes and exit AutoCAD 386 to the DOS
  126.           prompt.
  127.   3)   If you are using a batch file to load AutoCAD, put the
  128.        following lines in that batch file (otherwise put them in
  129.        the AUTOEXEC.BAT file on each node). (NOTE: the "%%s"
  130.        MUST BE LOWER CASE.)
  131.  
  132.      SET ACADPLCMD=NET PRINT %%s COM2  (Port redirected to
  133.      @PLOTTER)
  134.  
  135.      SET ACADPPCMD=NET PRINT/BINARY %%s LPT1 (Port redirected to
  136.      @PRINTER)
  137.      (Printer-plots must be sent in BINARY format or the printed
  138.      output may be cut off, distorted and/or spread out over
  139.      multiple pages.)
  140.  
  141. This will create a spooled file for every print or plotjob sent
  142. by that node. The files that begin with "R" are printer-plot
  143. files (raster) and the ones beginning with "V" are plot files
  144. (vector). These files, if not deleted, will quickly fill up a
  145. harddrive. The following lines can be added to a batch file to
  146. automatically delete the spooled files (see SAMPLE BATCH FILES:
  147. at end of this document):
  148.  
  149.   C:
  150.   CD\ACAD\TEMP :REM CD\ to the spooler directory.
  151.   DEL R*.*       :REM Delete all printer-plot files.
  152.   DEL V*.*       :REM Delete all plotter files.  
  153.   CD\
  154.  
  155. If the spool file directory is shared by more than one user, then
  156. all users' plot/printer-plot files will be deleted when any user
  157. exits AutoCAD. To prevent this, change the above command lines as
  158. follows:
  159.   
  160.   - Refer to note 7 above to get the network node name for the
  161. each node.
  162.   - Change "DEL R*.*" to "DEL R*.TBL" (when the network node name
  163. is "TBL")
  164.   - Change "DEL V*.*" to "DEL V*.TBL"
  165.   - Repeat for each node using the appropriate 3 letter network
  166. node name.  
  167.  
  168. Memory Managers:
  169. 1. AutoCAD 386 can be configured to use Extended memory or
  170. Expanded memory but not both. If the memory manager is not VCPI
  171. compliant, configure all memory as Extended; if it is VCPI
  172. compliant, configure all memory as Expanded. QEMM386, 386 to the
  173. MAX and MS-DOS's HIMEM.SYS in combination with EMM386.EXE are
  174. listed as compatible with LANtastic and will provide VCPI-com-
  175. pliant EMS. HIMEM.SYS that comes with MS-DOS 5.0 creates XMS
  176. which is not VCPI compliant and should not be used with AutoCAD
  177. 386 without also loading EMM386.EXE. Consult the AutoCAD
  178. Installation and Performance Guide for more information on
  179. compatible memory managers.
  180.  
  181. 2. Network drivers can be loaded into high memory using the
  182. utilities provided with the above listed memory managers,
  183. however, if the workstation is only used for AutoCAD 386, there
  184. is no benefit to loading programs high.
  185.  
  186. NOS Notes:
  187. A new feature in NOS 4.10, called IMMEDIATE DESPOOLING, can
  188. reduce printing and plotting time. To enable this new feature,
  189. run NET_MGR, select "Shared Resources Management" and enable
  190. "Immediate Despooling". Set "Despool Timeout" to 0 (which will
  191. display as "DISABLED"). It is important to set the despool
  192. timeout to zero for plotters and postscript printers. This must
  193. be set individually for each postscript printer or plotter device
  194. in "Shared Resources Management".
  195.  
  196. SAMPLE BATCH FILES:
  197. AUTOEXEC.BAT:
  198. PATH=C:\;C:\DOS;\BATCH;C:\UTILITY;C:\LANTASTI  
  199. AEX                                :REM Load netbios drivers. Can
  200.                                    be loaded high.
  201. AILANBIO 
  202. REDIR ALEX1 LOGINS=5               :REM Can be loaded high.
  203. LANCACHE CACHE_SIZE=256 TYPE=EMS   :REM 256K cache (using
  204.                                    expanded memory).
  205. SERVER                             :REM Server is optional. Can
  206.                                    be loaded high.
  207. NET LOGIN \\ALEX1 ALEX1              :REM Login to servers as
  208.                                      needed.
  209. NET USE LPT1 \\ALEX1\@PRINTER        :REM Redirect LPT1 to the
  210.                                      shared printer-plotter.
  211. NET USE COM2 \\ALEX1\@PLOTTER      :REM Redirect COM2 to the
  212.                                    shared plotter.
  213. NET LPT TIMEOUT 10      
  214. NET QUEUE HALT \\ALEX1 COM1          :REM If a server, halt
  215.                                      QUEUE for mouse/digitizer  
  216.                                      port.
  217. PROMPT=$P$G
  218. MENU                      
  219.  
  220.  
  221. LOADACAD.BAT:  
  222. REM Add "C:\ACAD;C:\ACAD\ADS;C:\ACAD\TEMP" to the DOS environment
  223. path.
  224. PATH=C:\;C:\DOS;C:\BATCH;C:\UTILITY;C:\LANTASTI;C:\ACAD;C:\ACAD\A
  225. DS;C:\ACAD\TEMP
  226. NET LPT TIMEOUT 0                       :REM Set LPT TIMEOUT to
  227.                                         zero.
  228. CD\ACAD\DWG
  229. SET ACADPPCMD=NET PRINT/BINARY %%s LPT1   :REM Printer-plotter
  230.                                           command. 
  231. SET ACADPLCMD=NET PRINT %%s COM2        :REM Plotter command.
  232. SET PLPADI=C:\ACAD\PLPHPLP.EXP            :REM Protected mode
  233.                                           plotter driver 
  234. SET DSPADI=C:\ET4\DLDVG256.EXP            :REM Protected-mode
  235. DLD video driver.
  236. SET DLDCFG=C:\ET4\                      :REM DLD configuration
  237.                                         file path.
  238. SET ACADPAGEDIR=C:\ACAD\TEMP            :REM AutoCAD 386 page
  239.                                         file directory.
  240. SET ACAD=C:\ACAD;C:\ACAD\SAMPLE;C:\ACAD\ADS
  241. SET ACADCFG=C:\ACAD
  242. ACAD                                 :REM Load AutoCAD 386.  
  243. SET ACADCFG=
  244. SET ACAD=                               :REM Clear environment
  245.                                         variables. 
  246. SET ACADPAGEDIR=
  247. SET DLDCFG=
  248. SET DSPADI=
  249. SET PLPADI=
  250. SET ACADPPCMD=
  251. SET ACADPLCMD=
  252. C:                                   :REM Remove all spooled
  253.                                      files.              
  254. CD\ACAD\TEMP
  255. DEL R*.*
  256. DEL V*.*             
  257. CD\
  258.  
  259.  
  260. FINAL NOTE:
  261. This document has been designed to provide a guideline for con-
  262. figuring AutoCAD 386 with LANtastic. Additional configuration may
  263. be necessary to accommodate your specific network setup. If a
  264. unique problem arises which we are unable to resolve either
  265. through phone contact with our technical support or through this
  266. bulletin, a problem report can be filed through our technical
  267. support staff. 
  268.  
  269.  
  270. ARTISOFT, Inc. makes no warranties as to the completeness or
  271. accuracy of this document. LANtastic is a trademark of ARTISOFT,
  272. Inc. Brand names and products are trademarks or registered
  273. trademarks of their respective companies.
  274.  
  275. Any questions or suggestions on this bulletin may be mailed to
  276. our offices:
  277.  
  278. Artisoft, Inc.
  279. 691 East River Road
  280. Tucson, AZ 85704
  281. ATTN: Compatibility Department / AutoCAD Support 
  282.  
  283. Vendor Info: